Title:The Comparison of Low and High-dose Scintigraphy findings in Patients with
Primary Parathyroid Lesions in which Intraoperative Gamma-probe was
Applied
Volume: 20
Author(s): Ceylan Sule*Yilmaz Necati
Affiliation:
- Nuclear Medicine, Gaziosmanpasa Taksim Training and Research Hospital, Osmanbey Street, Istanbul, Turkey
Keywords:
Hyperparathyroidism, Parathyroid adenoma, Gamma probe, Sestamibi, Radioactive material, Lesions.
Abstract:
Objective:
We aimed to evaluate the effectiveness of high-dose and low-dose use of radioactive material in intraoperative gamma probe application methods
in patients diagnosed with primary hyperparathyroidism and planned for surgery.
Methods:
47 patients with primary hyperparathyroidism underwent minimally-invasive parathyroid surgery (MIS) after preoperative imaging studies
consisting of ultrasonography (USG) and sestamibi parathyroid scintigraphy (SPS) showed a possible primary parathyroid lesion (PPL). All
patients received Tc-99 sestamibi on day-of-surgery imaging (DOSI) to help with the localization of a primary parathyroid lesion (PPL) via both
DOSI and intraoperative gamma probe (IGP). Patients in Group I were administered 20-25 mCi Tc-99m sestamibi (methoxy isobutyl isonitrile)
and images were obtained at the 20th and 120th minutes. Patients in Group II were administered 8-10 mCi doses and images were obtained at the
20th and 40th minutes. Two nuclear medicine specialists independently evaluated the images. Lesions in the localizations determined by DOSI and
IGP were compared with the histopathological results of these lesions.
Results:
47 patients, 35 females, and 12 males were included in the study. The mean age of 28 patients in the first group given the high dose was 54
(41-60), and the mean age was 48 (42-57) in the second group given the low dose (p=0.011). In the group given low-dose radioactive material
during intraoperative gamma probe application, the observer's sensitivity, specificity, positive, and negative predictive values for finding pathology
were 61.1, 100, 100, and 12.5, respectively. In the group given high-dose radioactive material, the same values were 90.9, 33.3, 50, and 83.3,
respectively. While the success of MIS increases with the use of DOSI and IGP in large lesions, the success decreases with the prolongation of the
accumulation time of the given dose.
Conclusion:
In the intraoperative gamma probe technique used in primary hyperparathyroidism patients, the method used with low-dose radioactive material
has lower sensitivity but higher specificity in estimating the post-operative pathology compared to the high-dose technique.